Home / Products / GRF-75C

GRF-75C

GRF-CMarine engine room

GRF-C · 55 kW · 4 steps:0.8 / 1.0 / 1.25 / 1.5 MPa

Motor55kW
Rated pressure0.8–1.5MPa
Capacity5.5–9.3m³/min
CoolingAir cooled / Water cooled
Weight1700kg
← Back to selector

Overview

GRF-75C GRF-C

GRF-75C belongs to the GRF-C series and is available in 4 pressure steps. Capacity differs at each rated pressure — pick the step closest to your actual working pressure rather than the highest one.

Before you specify

  • A machine rated above your working pressure can be regulated down, but capacity changes with pressure — use the table on this page.
  • For fluctuating demand add 10–20% headroom on peak flow so the unit is not running flat out.
  • Marine projects also need the class-rule edition, list/trim conditions and certificate scope confirmed.

Pressure steps

9.38.56.55.50.81.01.251.510.28.164m³/minMPa
Pressure (MPa)Capacity (m³/min)Noise dB(A)OutletDimensions L×W×H (mm)Weight (kg)
0.89.3—DN501750×1250×15201700
0.89.3—DN502200×1400×14101800
1.08.5—DN501750×1250×15201700
1.08.5—DN502200×1400×14101800
1.256.5—DN501750×1250×15201700
1.256.5—DN502200×1400×14101800
1.55.5—DN501750×1250×15201700
1.55.5—DN502200×1400×14101800

Pressure steps are fixed by the airend/motor pairing and cannot be changed after delivery.

Specifications

SeriesGRF-C
Motor55 kW
Rated pressure0.8–1.5 MPa
Capacity5.5–9.3 m³/min
CoolingAir cooled / Water cooled
OutletDN50
Dimensions1750×1250×1520 mm
Weight1700 kg
Pressure steps4 steps

Continue by application

Send us the duty point — we reply with a sized proposal

Flow, pressure, cooling water, power supply, class society and delivery port: six items are enough.

Online SelectorRequest a Quote