GRF-75C
GRF-CMarine engine roomGRF-C · 55 kW · 4 steps:0.8 / 1.0 / 1.25 / 1.5 MPa
Motor55kW
Rated pressure0.8–1.5MPa
Capacity5.5–9.3m³/min
CoolingAir cooled / Water cooled
Weight1700kg
Overview

GRF-75C belongs to the GRF-C series and is available in 4 pressure steps. Capacity differs at each rated pressure — pick the step closest to your actual working pressure rather than the highest one.
Before you specify
- A machine rated above your working pressure can be regulated down, but capacity changes with pressure — use the table on this page.
- For fluctuating demand add 10–20% headroom on peak flow so the unit is not running flat out.
- Marine projects also need the class-rule edition, list/trim conditions and certificate scope confirmed.
Pressure steps
| Pressure (MPa) | Capacity (m³/min) | Noise dB(A) | Outlet | Dimensions L×W×H (mm) | Weight (kg) |
|---|---|---|---|---|---|
| 0.8 | 9.3 | — | DN50 | 1750×1250×1520 | 1700 |
| 0.8 | 9.3 | — | DN50 | 2200×1400×1410 | 1800 |
| 1.0 | 8.5 | — | DN50 | 1750×1250×1520 | 1700 |
| 1.0 | 8.5 | — | DN50 | 2200×1400×1410 | 1800 |
| 1.25 | 6.5 | — | DN50 | 1750×1250×1520 | 1700 |
| 1.25 | 6.5 | — | DN50 | 2200×1400×1410 | 1800 |
| 1.5 | 5.5 | — | DN50 | 1750×1250×1520 | 1700 |
| 1.5 | 5.5 | — | DN50 | 2200×1400×1410 | 1800 |
Pressure steps are fixed by the airend/motor pairing and cannot be changed after delivery.
Specifications
SeriesGRF-C
Motor55 kW
Rated pressure0.8–1.5 MPa
Capacity5.5–9.3 m³/min
CoolingAir cooled / Water cooled
OutletDN50
Dimensions1750×1250×1520 mm
Weight1700 kg
Pressure steps4 steps